WegaConcept Espresso Coffee Machine

Thanks to its innovative software, the Wegaconcept has the ability to memorize the workload of the machine, thus adjusting the work and standby functions accordingly.

The multiple boiler technology, apart from the energy saving function which distributes power to the individual boilers only when required, guarantees an increased thermal heat stability of the coffee brewing boilers, giving us a perfect espresso.

The function of the nocturnal standby mode, combined with the MBT and SLS technology, allow the Wegaconcept to obtain a certified energy saving of 47,6% during the nocturnal rest period, and of 30% during the operational period (relative to an average weekly consumption of 15kg of coffee).

Particular attention has been dedicated to the operational safety of the Wegaconcept. The Wegaconcept offers 5 separate safety features on the services boiler, and 4 separate safety features on the individual coffee brewing boilers.


  WegaConcept Brochure

  Enquire Now


Electronic espresso coffee machine with programmable volumetric dosing.

ModelGroupsLength (mm)Depth (mm)Height (mm)Capacity (l)Weight (kg)Power (w)
22800600590895 - 1054790
33104060059013117 - 1296100
44128060059013142 - 1577730
  • colours_red   Red
  • colours_black   Black
  • colours_total black   Total Black
  • colours_white   White
  • colours_total white   Total White

Technical Characteristics

  1. Vertical flanged boiler for each brewing group, in copper and brass, with a 1,2 litre capacity, and 1150W heating element
  2. safety features on the services boiler:
    • The pressure switch disengages the power supply to the heating element if the pressure in the boiler reaches 1,5 bars
    • Should the pressure switch malfunction, the boiler safety valve opens when the pressure in the boiler reaches 2,0 bars
    • A temperature sensor, disconnects the heating element when it reaches 130°C, and gives a visual alarm signal on the display
    • A secondary safety sensor positioned internally in the boiler, disconnects the heating element should a temperature of 169°C be reached
    • A function on the Central Processing Unit, disconnects the heating element should it work uninterruptedly at 100% of its capacity for longer than 60 seconds
  3. safety features on the individual coffee brewing boilers:
    • A temperature sensor, disconnects the heating element when it reaches 130°C, and gives a visual alarm signal on the display
    • A secondary safety sensor, disconnects the heating element should a temperature of 150°C be reached
    • The SNCR valve opens when the pressure in the hydraulic circuit surpasses 12,5 bars
    • A function on the Central Processing Unit, disconnects the heating element should it work uninterruptedly at 100% of its capacity for longer than 45 seconds.
  4. USB port for the uploading and downloading of settings and parameters, in addition to software upgrades
  5. Hot water for tea, obtained by mixing fresh water from the incoming line, and steam from the services boiler
  6. Electronically controlled cup warmer
  7. Temperatures in the individual coffee brewing boilers, the group heads, and the services boiler, electronically controlled with a maximum fluctuation of 0,5°C either way
  8. Pump operating water pressure reading, together with incoming water pressure visible on the display
  9. Ambient humidity reading obtained by means of a hygrometer, and visible on the display
  10. Incoming water pressure reading, visible on the display

Display Functions

  1. Language options: Italian, English, German, French, Spanish, Portuguese
  2. Quantification and memorizing of selections effected by each group
  3. Option to control “save energy” function either manually or electronically
  4. Diagnostic messages obtained and displayed, in order to facilitate the operation of the Wegaconcept, in addition to the viewing of service and maintenance schedules
  5. Message indicating the necessary regeneration the water softener resins, or the substitution of the water filter cartridge
  6. Visualisation of the machine parameters, including the primary and secondary menu options
  7. Time and date settings and visualisation

Options

  1. Autosteamer